4.
LIMIT VALUES 4.1. For each of the six engine speeds at which the absorption coefficient is measured pursuant to paragraph 2.1 above, the nominal gas flow G, expressed in litres per second, shall be calculated by means of the following formulae: >PIC FILE= "T0010772"> where: V is the cylinder capacity of the engine expressed in litres ; and n is the engine speed in revolutions per minute. 4.2. For each engine speed the absorption coefficient of the exhaust gases shall not exceed the limit value given in the table in Annex VI. Where the value of the nominal flow is not one of those given in that table, the limit value applicable shall be obtained by interpolation on the principle of proportional parts.
← 3. · All articles · ANNEX IV →
Source: EUR-Lex (Cellar) · retrieved 2026-11-22 · Text as adopted (Official Journal); later amendments are not incorporated in this text.