ANNEX VII

1. SCOPE This annex defines the conditions to be met by opacimeters used in the tests described in Annexes III and IV. 2. BASIC SPECIFICATION FOR OPACIMETERS 2.1. The gas to be measured shall be confined in an enclosure having a non-reflecting internal surface. 2.2. In determining the effective length of the light path through the gas, account shall be taken of the possible influence of devices protecting the light source and the photoelectric cell. This effective length shall be indicated on the instrument. 2.3. >PIC FILE= "T0010776"> 3. CONSTRUCTION SPECIFICATIONS 3.1. General The design shall be such that under steady-speed operating conditions the smoke chamber is filled with smoke of uniform opacity. 3.2. Smoke chamber and opacimeter casing 3.2.1. The impingement on the photoelectric cell of stray light due to internal reflections or diffusion effects shall be reduced to a minimum (e.g. by finishing internal surfaces in matt black and by a suitable general layout). 3.2.2. The optical characteristics shall be such that the combined effect of diffusion and reflection does not exceed one unit on the linear scale when the smoke chamber is filled with smoke having an absorption coefficient near 1 77 m-1. 3.3. Light source The light source shall be an incandescent lamp with a colour temperature in the range 2 800 to 3 250 ºK. 3.4. Receiver 3.4.1. The receiver shall consist of a photoelectric cell with a spectral response curve similar to the photopic curve of the human eye (maximum response in the range 550/570 nm ; less than 4 per cent of that maximum response below 430 nm and above 680 nm). 3.4.2. The construction of the electrical circuit, including the indicating dial, shall be such that the current output from the photoelectric cell is a linear function of the intensity of the light received over the operating-temperature range of the photoelectric cell. 3.5. Measuring scales 3.5.1. >PIC FILE= "T0010777"> - either by the method described in item 4 of this Annex ; or through correlation with another type of opacimeter for which the effective length is known. 3.5.2. The relationship between the 0-100 linear scale and the light absorption coefficient k is given by the formula >PIC FILE= "T0010778"> where N is a reading on the linear scale and k the corresponding value of the absorption coefficient. 3.5.3. The indicating dial of the opacimeter shall enable an absorption coefficient of 1 77 m-1 to be read with an accuracy of 0 7025 m-1. 3.6. Setting and testing of the measuring apparatus 3.6.1. The electrical circuit of the photoelectric cell and of the indicating dial shall be adjustable so that the pointer can be reset at zero when the light flux passes through the smoke chamber filled with clean air or through a chamber having identical characteristics. 3.6.2. >PIC FILE= "T0010779"> 3.6.3. An intermediate check shall be carried our by placing in the smoke chamber a screen representing a gas whose known light-absorption coefficient k, measured as described in item 3.5.1, is between 1 76 m-1 and 1 78 m-1. The value of k must be known to within 0 7025 m-1. The check consists in verifying that this value does not differ by more than 0 705 m-1 from that read on the opacimeter indicating dial when the screen is introduced between the source of light and the photoelectric cell. 3.7. Opacimeter response 3.7.1. The response time of the electrical measuring circuit, being the time necessary for the indicating dial to reach 90 per cent of full-scale deflection on removal of a screen fully obscuring the photoelectric cell, shall be 0 79 to 1 71 second. 3.7.2. The damping of the electrical measuring circuit shall be such that the initial overswing beyond the final steady reading after any momentary variation in input (e.g. the calibration screen) does not exceed 4 per cent of that reading in linear scale units. 3.7.3. The response time of the opacimeter which is due to physical phenomena in the smoke chamber is the time between the entry of the gas into the measuring apparatus and the complete filling of the smoke chamber ; it shall not exceed 0 74 second. 3.7.4. These provisions shall apply solely to opacimeters used to measure opacity under free acceleration. 3.8. Pressure of the gas to be measured and of scavenging air 3.8.1. The pressure of the exhaust gas in the smoke chamber shall not differ by more than 75 mm (water gauge) from the atmospheric pressure. 3.8.2. The variations in the pressure of the gas to be measured and of the scavenging air shall not cause the absorption coefficient to vary by more than 0 705 m-1 in the case of a gas having an absorption coefficient of 1 77 m-1. 3.8.3. The opacimeter shall be equipped with appropriate devices for measuring the pressure in the smoke chamber. 3.8.4. The limits of pressure variation of gas and scavenging air in the smoke chamber shall be indicated by the manufacturer of the apparatus. 3.9. Temperature of the gas to be measured 3.9.1. At every point in the smoke chamber the gas temperature at the instant of measurement shall be between 70 ºC and a maximum temperature, specified by the opacimeter manufacturer, such that the readings over this temperature range do not vary by more than 0 71 m-1 if the chamber is filled with a gas having an absorption coefficient of 1 77 m-1. 3.9.2. The opacimeter shall be equipped with appropriate devices for measuring the temperature in the smoke chamber. 4. EFFECTIVE LENGTH "L" OF THE OPACIMETER 4.1. General 4.1.1. In some types of opacimeter the gas between the light source and the photoelectric cell, or between transparent parts protecting the source and the photoelectric cell, is not of constant opacity. In such cases the effective length L shall be that of a column of gas of uniform opacity which gives the same absorption of light as that obtained when the gas is admitted in a normal way into the opacimeter. 4.1.2. The effective length of the light path is obtained by comparing the reading N of the opacimeter operating normally with the reading No obtained with the opacimeter modified so that the test gas fills a well defined length Lo. 4.1.3. It will be necessary to take comparative readings in quick succession to determine the correction to be made for shifts of zero. 4.2. Method of assessment of L 4.2.1. The test gas shall be exhaust gas of constant opacity or a light-absorptive gas of a gravimetric density similar to that of the exhaust gas. 4.2.2. A column of length Lo of the opacimeter, which can be filled uniformly with the test gases, and the ends of which are substantially at right angles to the light path, shall be accurately determined. This length Lo shall be close to the presumed effective length of the opacimeter. 4.2.3. The mean temperature of the test gas in the smoke chamber shall be measured. 4.2.4. If necessary, an expansion tank of compact design and of sufficient capacity to damp the pulsations may be incorporated in the sampling line as near to the probe as possible. A cooler may also be fitted. The addition of the expansion tank and of the cooler must not unduly disturb the composition of the exhaust gas. 4.2.5. The test for determining the effective length shall consist of passing a sample of test gas alternately through the opacimeter operating normally and through the same apparatus modified as indicated in item 4.1.2. 4.2.5.1. The opacimeter readings shall be recorded continuously during the test with a recorder whose response time is equal to or shorter than that of the opacimeter. 4.2.5.2. With the opacimeter operating normally, the reading on the linear scale of opacity is N and that of the mean gas temperature expressed in Kelvin degrees is T. 4.2.5.3. With the known length Lo filled with the same test gas, the reading on the linear scale of opacity is No and that of the mean gas temperature expressed in Kelvin degrees is To. 4.2.6. The effective length will be >PIC FILE= "T0010780"> 4.2.7. The test shall be repeated with at least four test gases giving readings evenly spaced between the 20 and 80 on the linear scale. 4.2.8. The effective length L of the opacimeter will be the arithmetic mean of the effective lengths obtained as stated in item 4.6 with each of the gases.

· All articles ·

Source: EUR-Lex (Cellar) · retrieved 2026-11-22 · Text as adopted (Official Journal); later amendments are not incorporated in this text.