6.4.21.3. The periodic inspections shall consist of a visual inspection, the strength test, the leakproofness test and a check of satisfactory operations of the service equipment. The interval for periodic inspections shall be not more than five years. Packagings which have not been inspected within this five-year period shall be examined before carriage in accordance with a programme approved by the competent authority. They shall not be refilled before completion of the full programme for periodic inspections.