Data-quality objectives The following data-quality objectives for the required accuracy of assessment methods, of minimum time coverage and of data capture of measurement are laid down to guide quality-assurance programmes. >TABLE> The accuracy of the measurement is defined as laid down in the "Guide to the Expression of Uncertainty of Measurements" (ISO 1993) or in ISO 5725-1 "Accuracy (trueness and precision) of measurement methods and results" (1994). The percentages in the table are given for individual measurements averaged, over the period considered, by the limit value, for a 95 % confidence interval (bias + two times the standard deviation). The accuracy for continuous measurements should be interpreted as being applicable in the region of the appropriate limit value. The accuracy for modelling and objective estimation is defined as the maximum deviation of the measured and calculated concentration levels, over the period considered by the limit value, without taking into account the timing of the events. The requirements for minimum data capture and time coverage do not include losses of data due to the regular calibration or the normal maintenance of the instrumentation. By way of derogation, Member States may apply random measurements instead of continuous measurements for particulate matter and lead if they can demonstrate to the Commission that accuracy within the 95 % confidence interval with respect to continuous monitoring is within 10 %. Random sampling must be spread evenly over the year.