The reference method for the measurement of arsenic, cadmium and nickel concentrations in ambient air is currently being standardised by CEN and shall be based on manual PM_(10) sampling equivalent to EN 12341, followed by digestion of the samples and analysis by Atomic Absorption Spectrometry or ICP Mass Spectrometry. In the absence of a CEN standard method, Member States are allowed to use national standard methods or ISO standard methods.