(a)
Text of image mPT = mf msep × medf 1000 where: The total mass of equivalent diluted exhaust gas mass over the cycle shall be determined as follows: Text of image medf = i = n Σ i = 1 qmedf,i × 1 f Text of image qmedf,i = qmew,i × rd,i Text of image rd,i = qmdew,,i (qmdew,,i - qmdw,,i) where: m f | = | particulate mass sampled over the cycle, mg m sep | = | mass of diluted exhaust gas passing the particulate collection filters, kg m edf | = | mass of equivalent diluted exhaust gas over the cycle, kg q medf,i | = | instantaneous equivalent diluted exhaust mass flow rate, kg/s q mew,i | = | instantaneous exhaust mass flow rate, kg/s r d,i | = | instantaneous dilution ratio q mdew,i | = | instantaneous diluted exhaust mass flow rate through dilution tunnel, kg/s q mdw,i | = | instantaneous dilution air mass flow rate, kg/s f | = | data sampling rate, Hz n | = | number of measurements