Wavelength^(a) [nm] Aperture Duration [s] 10^(1) — 10^(2) 10^(2) — 10^(4) 10^(4) — 3 · 10^(4) UVC 180 — 280 H = 30 [J m^(-2)] 280 — 302 3,5 mm UVB 303 H = 40 [J m^(-2)] 304 H = 60 [J m^(-2)] 305 H = 100 [J m^(-2)] 306 H = 160 [J m^(-2)] 307 H = 250 [J m^(-2)] 308 H = 400 [J m^(-2)] 309 H = 630 [J m^(-2)] 310 H = 1,0 · 10^(3) [J m^(-2)] 311 H = 1,6 · 10^(3) [J m^(-2)] 312 H = 2,5 · 10^(3) [J m^(-2)] 313 H = 4,0 · 10^(3) [J m^(-2)] 314 H = 6,3 · 10^(3) [J m^(-2)] UVA 315 — 400 H = 10^(4) [J m^(-2)] Visible 400 — 700 400 — 600 Photochemical ^(b) Retinal damage 7 mm H = 100 C_(B) [J m^(-2)] (γ = 11 mrad)^(d) E = 1 C_(B) [W m^(-2)]; (γ = 1,1 t^(0,5) mrad)^(d) E = 1 C_(B) [W m^(-2)] (γ = 110 mrad) ^(d) 400 — 700 Thermal ^(b) Retinal damage if α < 1,5 mrad then E = 10 [W m^(-2)] if α > 1,5 mrad and t ≤ T_(2) then H = 18 C_(E) t^(0,75) [J m^(-2)] if α > 1,5 mrad and t > T_(2) then E = 18 C_(E) T_(2)^(-0,25) [W m^(-2)] IRA 700 — 1 400 7 mm if α < 1,5 mrad then E = 10 C_(A) C_(C) [W m^(-2)] if α > 1,5 mrad and t ≤ T_(2) then H = 18 C_(A) C_(C) C_(E) t^(0,75) [J m^(-2)] if α > 1,5 mrad and t > T_(2) then E = 18 C_(A) C_(C) C_(E) T_(2)^(-0,25) [W m^(-2)] (not to exceed 1 000 W m^(-2)) IRB & IRC 1 400 — 10^(6) See^(c) E = 1 000 [W m^(-2)] a If the wavelength or another condition of the laser is covered by two limits, then the more restrictive applies. b For small sources subtending an angle of 1,5 mrad or less, the visible dual limits E from 400 nm to 600 nm reduce to the thermal limits for 10 s≤ t<T_(1) and to photochemical limits for longer times. For T_(1) and T_(2) see Table 2.5. The photochemical retinal hazard limit may also be expressed as a time integrated radiance G = 10^(6) C_(B) [J m^(-2) sr^(-1)] for t > 10s up to t = 10 000 s and L = 100 C_(B) [W m^(-2) sr^(-1)] for t > 10 000 s. For the measurement of G and L γ_(m) must be used as averaging field of view. The official border between visible and infrared is 780 nm as defined by the CIE. The column with wavelength band names is only meant to provide better overview for the user. (The notation G is used by CEN; the notation L_(t) is used by CIE; the notation L_(P) is used by IEC and CENELEC.) c For wavelength 1 400 — 10^(5) nm: aperture diameter = 3,5 mm; for wavelength 10^(5) — 10^(6) nm: aperture Diameter = 11 mm. d For measurement of the exposure value the consideration of γ is defined as follows: If α (angular subtense of a source) > γ (limiting cone angle, indicated in brackets in the corresponding column) then the measurement field of view γ_(m) should be the given value of γ. (If a larger measurement field of view is used, then the hazard would be overestimated). If α < γ then the measurement field of view γ_(m) must be large enough to fully enclose the source but is otherwise not limited and may be larger than γ.

· All articles ·

Source: EUR-Lex (Cellar) · retrieved 2026-11-24 · Text as adopted (Official Journal); later amendments are not incorporated in this text.