lexiara

3.

The exposure from any single pulse within a group of pulses shall not exceed the single‐pulse exposure limit value multiplied by a cumulative-thermal correction factor C_(p)=N^(-0,25), where N is the number of pulses. This rule applies only to exposure limits to protect against thermal injury, where all pulses delivered in less than T_(min) are treated as a single pulse. Parameter Valid spectral range (nm) Value T_(min) 315 <λ≤ 400 T_(min) = 10 ^(-9) s (= 1 ns) 400 <λ≤ 1050 T_(min) = 18· 10 ^(-6) s (= 18 μs) 1050 <λ≤ 1400 T_(min) = 50· 10 ^(-6) s (= 50 μs) 1400 <λ≤ 1500 T_(min) = 10 ^(-3) s (= 1 ms) 1500 <λ≤ 1800 T_(min) = 10 s 1800 <λ≤ 2600 T_(min) = 10 ^(-3) s (= 1 ms) 2600 <λ≤ 10 ^(6) T_(min) = 10 ^(-7) s (= 100 ns)

· All articles ·

Source: EUR-Lex (Cellar) · retrieved 2026-11-24 · Text as adopted (Official Journal); later amendments are not incorporated in this text.