1.2. Vision The following requirements as regards vision must be complied with: aided or unaided distance visual acuity: 1,0; minimum of 0,5 for the worse eye, maximum corrective lenses: hypermetropia + 5/myopia -8. Derogations are authorised in exceptional cases and after having obtained the opinion of an eye specialist. The medical doctor then takes the decision, near and intermediate vision: sufficient, whether aided or unaided, contact lenses and glasses are authorised when periodically checked by a specialist, normal colour vision: use of a recognised test, such as Ishihara, as well as another recognised test if required, field of vision: full, vision for both eyes: effective; not required when person has adequate adaptation and sufficient compensation experience. Only in case he lost binocular vision after starting his job, binocular vision: effective, recognition of colour signals: the test shall be based on recognition of single colours and not on relative differences, sensitivity to contrasts: good, no progressive eye diseases, lens implants, keratotomies and keratectomies are allowed only on condition that they are checked on a yearly basis or at intervals set by the medical doctor, ability to withstand dazzle, coloured contact lenses and photochromatic lenses are not allowed. UV filter lenses are allowed.