cpt_VII__para__50
The value of HDD (Heating Degree Days) should be taken as the average of annual HDD values for the incineration facility location, calculated for a period of 20 consecutive years before the year for which CCF is calculated. For the calculation of the value of HDD the following method established by Eurostat should be applied: HDD is equal to (18 °C – Tm) × d if Tm is lower than or equal to 15 °C (heating threshold) and is nil if Tm is greater than 15 °C; where Tm is the mean (Tmin + Tmax)/2 outdoor temperature over a period of d days. Calculations are to be executed on a daily basis (d = 1), added up to a year.
← cpt_VII__para__49 · All articles · cpt_VII__para__51 →
Source: EUR-Lex CELLAR · retrieved 2026-09-08 · Text as consolidated on 2025-10-16; changes after this date are not shown.