ANNEX II
1.1. This Annex sets out the in-service conformity requirements for vehicles type approved to this Regulation. 2.1. The audit of in-service conformity by the approval authority shall be conducted on the basis of any relevant information that the manufacturer has, under the same procedures as those for the conformity of production defined in Article 12(1) and (2) of Directive 2007/46/EC and in points 1 and 2 of Annex X to that Directive. Information from approval authority and Member State surveillance testing may complement the in-service monitoring reports supplied by the manufacturer. 2.2. The figure referred to under point 9 of Appendix 2 to this Annex and Figure 4/2 of Appendix 4 to UN/ECE Regulation 83 illustrates the procedure for in-service conformity checking. The process for in-service conformity is described in Appendix 3 to this Annex. 2.3. As part of the information provided for the in-service conformity control, at the request of the approval authority, the manufacturer shall report to the type-approval authority on warranty claims, warranty repair works and OBD faults recorded at servicing, according to a format agreed at type-approval. The information shall detail the frequency and substance of faults for emissions related components and systems. The reports shall be filed at least once a year for each vehicle model for the duration of the period defined in Article 9(4) of this Regulation. The in-service family may be defined by basic design parameters which shall be common to vehicles within the family. Accordingly, vehicle types may be considered as belonging to the same in-service family if they have in common, or within the stated tolerances, the following parameters: 2.4.1. combustion process (two stroke, four stroke, rotary); 2.4.2. number of cylinders; 2.4.3. configuration of the cylinder block (in-line, V, radial, horizontally opposed, other). The inclination or orientation of the cylinders is not a criteria); 2.4.4. method of engine fuelling (e.g. indirect or direct injection); 2.4.5. type of cooling system (air, water, oil); 2.4.6. method of aspiration (naturally aspirated, pressure charged); 2.4.7. fuel for which the engine is designed (petrol, diesel, NG, LPG, etc.). Bi fuelled vehicles may be grouped with dedicated fuel vehicles providing one of the fuels is common; 2.4.8. type of catalytic converter (three-way catalyst, lean NOx trap, SCR, lean NOx catalyst or other(s)); 2.4.9. type of particulate trap (with or without); 2.4.10. exhaust gas recirculation (with or without, cooled or non cooled); and 2.4.11. engine cylinder capacity of the largest engine within the family minus 30 %. An audit of in-service conformity will be conducted by the approval authority on the basis of information supplied by the manufacturer. Such information shall include in particular, the following: 2.5.1. the name and address of the manufacturer; 2.5.2. the name, address, telephone and fax numbers and e-mail address of his authorised representative within the areas covered by the manufacturer’s information; 2.5.3. the model name(s) of the vehicles included in the manufacturer’s information; 2.5.4. where appropriate, the list of vehicle types covered within the manufacturer’s information, i.e. the in-service family group in accordance with section 2.1; 2.5.5. the vehicle identification number (VIN) codes applicable to these vehicle types within the in-service family (VIN prefix); 2.5.6. the numbers of the type-approvals applicable to these vehicle types within the in-service family, including, where applicable, the numbers of all extensions and field fixes/recalls (re-works); 2.5.7. details of extensions, field fixes/recalls to those type-approvals for the vehicles covered within the manufacturer’s information (if requested by the approval authority); 2.5.8. the period of time over which the manufacturer’s information was collected; 2.5.9. the vehicle build period covered within the manufacturer’s information (e.g. vehicles manufactured during the 2007 calendar year); 2.5.10. the manufacturer’s in-service conformity checking procedure, including: vehicle location method; vehicle selection and rejection criteria; test types and procedures used for the programme; the manufacturer’s acceptance/rejection criteria for the in-service family group; geographical area(s) within which the manufacturer has collected information; sample size and sampling plan used; 2.5.11. the results from the manufacturer’s in-service conformity procedure, including: identification of the vehicles included in the programme (whether tested or not). The identification shall include the following: model name, vehicle identification number (VIN), vehicle registration number, date of manufacture, region of use (where known), tyres fitted, the reason(s) for rejecting a vehicle from the sample; service history for each vehicle in the sample (including any re-works); repair history for each vehicle in the sample (where known); test data, including the following: date of test, location of test, distance indicated on vehicle odometer, test fuel specifications (e.g. test reference fuel or market fuel), test conditions (temperature, humidity, dynamometer inertia weight), dynamometer settings (e.g. power setting), test results (from at least three different vehicles per family), 2.5.12. records of indication from the OBD system. 3.1. The information gathered by the manufacturer shall be sufficiently comprehensive to ensure that in-service performance can be assessed for normal conditions of use as defined in section 1. The manufacturer’s sampling shall be drawn from at least two Member States with substantially different vehicle operating conditions. Factors such as differences in fuels, ambient conditions, average road speeds, and urban/highway driving split shall be taken into consideration in the selection of the Member States. 3.2. In selecting the Member States for sampling vehicles, the manufacturer may select vehicles from a Member State that is considered to be particularly representative. In this case, the manufacturer shall demonstrate to the approval authority which granted the type approval that the selection is representative (e.g. by the market having the largest annual sales of a vehicle family within the Community). When an in-service family requires more than one sample lot to be tested as defined in paragraph 3.5., the vehicles in the second and third sample lots shall reflect different vehicle operating conditions from those selected for the first sample. 3.3. The emissions testing may be done at a test facility which is located in a different market or region from where the vehicles have been selected. 3.4. The in-service conformity tests by the manufacturer shall be continuously carried out reflecting the production cycle of applicable vehicles types within a given in-service vehicle family. The maximum time period between commencing two in-service conformity checks shall not exceed 18 months. In the case of vehicle types covered by an extension to the type-approval that did not require an emissions test, this period may be extended up to 24 months. 3.5. When applying the statistical procedure defined in Appendix 2, the number of sample lots shall depend on the annual sales volume of an in-service family in the Community, as defined in the following table: Registrations per calendar year | Number of sample lots up to 100 000 | 1 100 001 to 200 000 | 2 above 200 000 | 3 On the basis of the audit referred to in Section 2 the approval authority shall adopt one of the following decisions and actions: decide that the in-service conformity of a vehicle type or a vehicle in-service family is satisfactory and not take any further action; decide that the data provided by the manufacturer is insufficient to reach a decision and request additional information or test data from the manufacturer; decide that based on data from the approval authority or Member State surveillance testing programmes, that information provided by the manufacturer is insufficient to reach a decision and request additional information or test data from the manufacturer; decide that the in-service conformity of a vehicle type, that is part of an in-service family, is unsatisfactory and proceed to have such vehicle type tested in accordance with Appendix 1. 4.1. Where type 1 tests are considered necessary to check the conformity of emission control devices with the requirements for their performance while in service, such tests shall be carried out using a test procedure meeting the statistical criteria defined in Appendix 2 4.2. The approval authority, in cooperation with the manufacturer, shall select a sample of vehicles with sufficient mileage whose use under normal conditions can be reasonably assured. The manufacturer shall be consulted on the choice of the vehicles in the sample and allowed to attend the confirmatory checks of the vehicles. 4.3. The manufacturer shall be authorised, under the supervision of the approval authority, to carry out checks, even of a destructive nature, on those vehicles with emission levels in excess of the limit values with a view to establishing possible causes of deterioration which cannot be attributed to the manufacturer (e.g. use of leaded petrol before the test date) Where the results of the checks confirm such causes, those test results shall be excluded from the conformity check.
← d1e34-56-1__para__12 · All articles · IN-SERVICE CONFORMITY →
Source: EUR-Lex (Cellar) · retrieved 2026-11-20 · Text as adopted (Official Journal); later amendments are not incorporated in this text.