anx_IX__table__6
Parameter | Unit | Limits (23) | Test method Minimum | Maximum Research octane number, RON | | 95,0 | — | EN 25164 prEN ISO 5164 Motor octane number, MON | | 85,0 | — | EN 25163 prEN ISO 5163 Density at 15 °C | kg/m3 | 743 | 756 | ISO 3675 EN ISO 12185 Vapour pressure | kPa | 56,0 | 95,0 | EN ISO 13016-1 (DVPE) Water content | % v/v | | 0,015 | ASTM E 1064 Distillation: | | | | — evaporated at 70 °C | % v/v | 24,0 | 44,0 | EN-ISO 3405 — evaporated at 100 °C | % v/v | 50,0 | 60,0 | EN-ISO 3405 — evaporated at 150 °C | % v/v | 82,0 | 90,0 | EN-ISO 3405 — final boiling point | °C | 190 | 210 | EN-ISO 3405 Residue | % v/v | — | 2,0 | EN-ISO 3405 Hydrocarbon analysis: | | | | — olefins | % v/v | 3,0 | 13,0 | ASTM D 1319 — aromatics | % v/v | 29,0 | 35,0 | ASTM D 1319 — benzene | % v/v | — | 1,0 | EN 12177 — saturates | % v/v | Report | ASTM D 1319 Carbon/hydrogen ratio | | Report | Carbon/oxygen ratio | | Report | Induction period (24) | minutes | 480 | — | EN-ISO 7536 Oxygen content (25) | % m/m | Report | EN 1601 Existent gum | mg/ml | — | 0,04 | EN-ISO 6246 Sulphur content (26) | mg/kg | — | 10 | EN ISO 20846 EN ISO 20884 Copper corrosion | | — | Class 1 | EN-ISO 2160 Lead content | mg/l | — | 5 | EN 237 Phosphorus content (27) | mg/l | — | 1,3 | ASTM D 3231 Ethanol (25) | % v/v | 4,7 | 5,3 | EN 1601 EN 13132
← anx_IX__para__6 · All articles · anx_IX__para__7 →
Source: EUR-Lex (Cellar) · retrieved 2026-11-20 · Text as adopted (Official Journal); later amendments are not incorporated in this text.