lexiara

anx_XVI__para__22

8.3.1. A ‘no engine restart after countdown’ approach allows a countdown of restarts or distance remaining once the inducement system activates. Engine starts initiated by the vehicle control system, such as start-stop systems, are not included in this countdown. Engine restarts shall be prevented immediately after the reagent tank becomes empty or a distance equivalent to a complete tank of fuel has been exceeded since the activation of the inducement system, whichever occurs earlier.

· All articles ·

Source: EUR-Lex (Cellar) · retrieved 2026-11-20 · Text as adopted (Official Journal); later amendments are not incorporated in this text.