3.6. Reporting and increasing counters
3.6.1. The OBD system shall report in accordance with the ISO 15031-5 specifications the ignition cycle counter and general denominator as well as separate numerators and denominators for the following monitors, if their presence on the vehicle is required by this Annex: Catalysts (each bank to be reported separately), Oxygen/exhaust gas sensors, including secondary oxygen sensors (each sensor to be reported separately), Evaporative system, EGR system, VVT system, Secondary air system, Particulate filter, NOx aftertreatment system (e.g. NOx adsorber, NOx reagent/catalyst system), Boost pressure control system, 3.6.2. For specific components or systems that have multiple monitors, which are required to be reported by this section (e.g. oxygen sensor bank 1 may have multiple monitors for sensor response or other sensor characteristics), the OBD system shall separately track numerators and denominators for each of the specific monitors and report only the corresponding numerator and denominator for the specific monitor that has the lowest numerical ratio. If two or more specific monitors have identical ratios, the corresponding numerator and denominator for the specific monitor that has the highest denominator shall be reported for the specific component. 3.6.3. All counters, when incremented, shall be incremented by an integer of one. 3.6.4. The minimum value of each counter is 0, the maximum value shall not be less than 65 535, notwithstanding any other requirements on standardised storage and reporting of the OBD system. 3.6.5. If either the numerator or denominator for a specific monitor reaches its maximum value, both counters for that specific monitor shall be divided by two before being incremented again according to the provisions set in sections 3.2 and 3.3. If the ignition cycle counter or the general denominator reaches its maximum value, the respective counter shall change to zero at its next increment according to the provisions set in sections 3.4 and 3.5, respectively. 3.6.6. Each counter shall be reset to zero only when a non-volatile memory reset occurs (e.g. reprogramming event, etc.) or, if the numbers are stored in keep-alive memory (KAM), when KAM is lost due to an interruption in electrical power to the control module (e.g. battery disconnect, etc.). 3.6.7. The manufacturer shall take measures to ensure that the values of numerator and denominator can not be reset or modified, except in cases provided for explicitly in this section.
← — · All articles · sec_3_6__3__para →
Source: EUR-Lex (Cellar) · retrieved 2026-11-20 · Text as adopted (Official Journal); later amendments are not incorporated in this text.