4. Experimentally Determining the R-Factor for Bench Ageing Durability Procedures
The R-Factor is the catalyst thermal reactivity coefficient used in the bench ageing time (BAT) equation. Manufacturers may determine the value of R experimentally using the following procedures. 4.1.1. Using the applicable bench cycle and ageing bench hardware, age several catalysts (minimum of 3 of the same catalyst design) at different control temperatures between the normal operating temperature and the damage limit temperature. Measure emissions (or catalyst inefficiency (1-catalyst efficiency)) for each exhaust constituent. Assure that the final testing yields data between one- and two-times the emission standard. 4.1.2. Estimate the value of R and calculate the effective reference temperature (Tr) for the bench ageing cycle for each control temperature according to Paragraph 2.4.4 of Annex VII. 4.1.3. Plot emissions (or catalyst inefficiency) versus ageing time for each catalyst. Calculate the least-squared best-fit line through the data. For the data set to be useful for this purpose the data should have an approximately common intercept between 0 and 6 400 km. See the following graph for an example. 4.1.4. Calculate the slope of the best-fit line for each ageing temperature. 4.1.5. Plot the natural log (ln) of the slope of each best-fit line (determined in step 4.1.4.) along the vertical axis, versus the inverse of ageing temperature (1/(ageing temperature, deg K)) along the horizontal axis, Calculate the least squared best-fit lines through the data. The slope of the line is the R-factor. See the following graph for an example. Catalyst Ageing 2 × std 1 × std Emissions Temp A Temp B Temp C Ageing Time (hours) 4.1.6. Compare the R-factor to the initial value that was used in Step 4.1.2. If the calculated R-factor differs from the initial value by more than 5 %, choose a new R-factor that is between the initial and calculated values, and then repeat Steps 2-6 to derive a new R-factor. Repeat this process until the calculated R-factor is within 5 % of the initially assumed R-factor. 4.1.7. Compare the R-factor determined separately for each exhaust constituent. Use the lowest R-factor (worst case) for the BAT equation. Determining the R-Factor -Ln(slope) 1/TA 1/TB 1/TC 1/(ageing temperature) slope = rate of change in emissions/time
← sec_3__11__para__16 · All articles · sec_4__7__para →
Source: EUR-Lex (Cellar) · retrieved 2026-11-20 · Text as adopted (Official Journal); later amendments are not incorporated in this text.