IN NEW CLASS B, C AND D SHIPS OF LESS THAN 24 METRES IN LENGTH AND EXISTING CLASS B SHIPS:

one of the fixed fire-extinguishing systems specified in paragraph .1 above, and in addition in any space containing internal combustion engines, or oil-fuel settling tanks or oil-fuel units, one foam fire extinguisher of at least 45 litres capacity or one carbon dioxide extinguisher of at least 16 kg capacity shall be provided, and one portable fire extinguisher suitable for extinguishing oil fires for each 736 kW or part thereof of such machinery; provided that not less than two nor more than six such extinguishers shall be required in any such space. The use of low-expansion foam fixed system in lieu of some of the six portable fire extinguishers required by this regulation is permitted.