NEW CLASS B, C AND D AND EXISTING CLASS B SHIPS:

All windows and sidescuttles in bulkheads within accommodation and service spaces and control stations other than those to which the provisions of Regulation 7.5 apply, shall be so constructed as to preserve the integrity requirements of the type of bulkheads in which they are fitted. In new class B, C and D ships constructed on or after 1 January 2003 this shall be determined in accordance with the IMO Fire Test Procedures Code. Notwithstanding the requirements of the tables in Regulations 4 and 5, all windows and sidescuttles in bulkheads separating accommodation and service spaces and control stations from weather shall be constructed with frames of steel or other suitable material. The glass shall be retained by a metal glazing bed or angle.