.1
Not later than 1 October 2000: All accommodation and service spaces, stairway enclosures and corridors shall be equipped with a smoke detection and alarm system of an approved type, and complying with the requirements of Regulation II-2/A/9. Such system need not be fitted in private bathrooms, and spaces having little or no fire risk such as voids and similar spaces. Detectors operated by heat instead of smoke shall be installed in galleys. Smoke detectors connected to the fire detection and alarm system shall also be fitted above ceilings in stairways and corridors in the areas where ceilings are of combustible construction. Hinged fire doors in stairway enclosures, main vertical zone bulkheads and galley boundaries which are normally kept open shall be self-closing and be capable of release from a central control station and from a position at the door. A panel shall be placed in a continuously manned central control station to indicate whether the fire doors in stairway enclosures, main vertical zone bulkheads and galley boundaries are closed. Exhaust ducts from galley ranges in which grease or fat is likely to accumulate and which pass through accommodation spaces or spaces containing combustible materials shall be constructed of ‘A’ class divisions. Each galley range exhaust duct shall be fitted with: a grease trap readily removable for cleaning unless an alternative grease removal process is fitted; a fire damper located in the lower end of the duct; arrangements operable from within the galley for shutting off the exhaust fans; fixed means for extinguishing a fire within the duct; and suitably located hatches for inspection and cleaning. Only public toilets, lifts, lockers of non-combustible materials providing storage for safety equipment and open information counters may be located within the stairway enclosure boundaries. Other existing spaces within the stairway enclosure: shall be emptied, permanently closed and disconnected from the electrical system; or shall be separated from the stairway enclosure by the provision of ‘A’ class divisions in accordance with Regulation 5. Such spaces may have direct access to stairway enclosures by the provision of ‘A’ class doors in accordance with Regulation 5, and subject to a sprinkler system being provided in these spaces. However, cabins shall not directly open into the stairway enclosure. Spaces other than public spaces, corridors, public toilets, special category spaces, other stairways required by Regulation 6.1.5, open deck spaces and spaces covered by paragraph .3.4.2 are not permitted to have direct access to stairway enclosures. Existing machinery spaces of category (10) described in Regulation II-2/B/4 and back offices for information counters which open directly into the stairway enclosure may be retained, provided that they are protected by smoke detectors and that back offices for information counters contain only furniture of restricted fire risk. In addition to the emergency lighting required by Regulations II-1/D/3 and III/5.3, the means of escape including stairways and exits shall be marked, at all points of the escape route including angles and intersections, by lighting or photoluminescent strip indicators placed not more than 0,3 metres above the deck. The marking must enable passengers to identify all the routes of escape and readily identify the escape exits. If electric illumination is used, it shall be supplied by the emergency source of power and it shall be so arranged that the failure of any single light or cut in a lighting strip, will not result in the marking being ineffective. Additionally, all escape route signs and fire equipment location markings shall be of photoluminescent material or marked by lighting. The Administration of the flag State shall ensure that such lighting or photoluminescent equipment have been evaluated, tested and applied in accordance with the guidelines as given in IMO Resolution A.752 (18) or in ISO Standard 15370-2001. A general emergency alarm system shall be provided. The alarm shall be audible throughout all the accommodation and normal crew working spaces and open decks, and its sound pressure level shall comply with the standards of the Code on Alarms and Indicators adopted by IMO in Resolution A.686 (17). A public address system or other effective means of communication shall be available throughout the accommodation, public and service spaces, control stations and open decks. Furniture in stairway enclosures shall be limited to seating. It shall be fixed, limited to six seats on each deck in each stairway enclosure, be of restricted fire risk, and shall not restrict the passenger escape route. The Administration of the flag State may permit additional seating in the main reception area within a stairway enclosure, if it is fixed, non-combustible, and does not restrict the passenger escape route. Furniture shall not be permitted in passenger and crew corridors forming escape routes in cabin areas. In addition to the above, lockers of non-combustible material, providing storage for safety equipment required by regulations, may be permitted.
← anx_I__cpt_1__cpt_3__cpt_2__cpt_17__text_1 · All articles · anx_I__cpt_1__cpt_3__cpt_2__cpt_17__item_1__text_1 →
Source: EUR-Lex (Cellar) · retrieved 2026-11-10 · Text as adopted (Official Journal); later amendments are not incorporated in this text.