NEW CLASS B, C AND D AND EXISTING CLASS B SHIPS:
.2 In special category spaces the number and disposition of the means of escape both below and above the bulkhead deck shall be to the satisfaction of the Administration of the flag State and in general the safety of access to the embarkation deck shall be at least equivalent to that provided under paragraphs .1.1, .1.2, .1.5 and .1.6. In new class B, C and D ships constructed on or after 1 January 2003, such spaces shall be provided with designated walkways to the means of escape with a breadth of at least 600 mm, and where practicable and reasonable those designated longitudinal walkways shall raise at least 150 mm above the deck surface. The parking arrangements for the vehicles shall maintain the walkways clear at all times. One of the escape routes from the machinery spaces where the crew is normally employed shall avoid direct access to any special category space. Hoistable drive-up/down ramps to platform decks must not be capable of blocking the approved escape routes when in lowered position. .3.1 Two means of escape shall be provided from each machinery space. In particular, the following provisions shall be complied with: Where the space is below the bulkhead deck the two means of escape shall consist of either: two sets of steel ladders as widely separated as possible, leading to doors in the upper part of the space similarly separated and from which there is access to the appropriate lifeboat and life-raft embarkation decks. In new ships, one of these ladders shall provide continuous fire shelter from the lower part of the space to a safe position outside the space. In new class B, C and D ships constructed on or after 1 January 2003 that ladder shall be located within a protected enclosure that satisfies Regulation II-2/B/4, category (2) or II-2/B/5, category (4), as appropriate, from the lower part of the space it serves to a safe position outside the space. Self-closing fire doors of the same fire integrity standards shall be fitted in the enclosure. The ladder shall be fixed in such a way that heat is not transferred into the enclosure through non-insulated fixing points. The protected enclosure shall have minimum internal dimensions of at least 800 mm × 800 mm, and shall have emergency lighting provisions; or one steel ladder leading to a door from which access is provided to the embarkation deck and additionally, in the lower part of the space and in a position well separated from the ladder referred to, a steel door capable of being operated from each side and which provides access to a safe escape route from the lower part of the space to the embarkation deck. Where the space is above the bulkhead deck, the two means of escape shall be as widely separated as possible and the doors leading from such means of escape shall be a position from which access is provided to the appropriate lifeboat and life-raft embarkation decks. Where such means of escape require the use of ladders, these shall be of steel. From spaces for monitoring of operation of machinery, and from work spaces, there shall be at least two means of escape, of which one shall be independent of the machinery space and give access to the embarkation deck. The underside of stairs in machinery spaces shall be shielded.
← anx_I__cpt_1__cpt_3__cpt_2__cpt_6__cpt_1__cpt_1__cpt_6__item_2__item_2__item_3__text_1 · All articles · anx_I__cpt_1__cpt_3__cpt_2__cpt_6__cpt_2__cpt_1 →
Source: EUR-Lex (Cellar) · retrieved 2026-11-10 · Text as adopted (Official Journal); later amendments are not incorporated in this text.