CLASS B, C AND D SHIPS CONSTRUCTED ON OR AFTER 1 JANUARY 2003:
Instead of .5: the following paragraph .5a shall apply: The requirements for ‘A’ class integrity of the outer boundaries of a ship shall not apply to glass partitions, windows and sidescuttles, provided that there is no requirement for such boundaries to have a ‘A’ class integrity in Regulation 10. The requirements for ‘A’ class integrity of the outer boundaries of the ship shall not apply to exterior doors, except for those in superstructures and deckhouses facing life-saving appliances. embarkation and external assembly station areas, external stairs and open decks used for escape routes. Stairway enclosure doors need not meet this requirement.
← anx_I__cpt_1__cpt_3__cpt_2__cpt_8__cpt_3__item_1__text_1 · All articles · anx_I__cpt_1__cpt_3__cpt_2__cpt_8__cpt_4__text_1 →
Source: EUR-Lex (Cellar) · retrieved 2026-11-10 · Text as adopted (Official Journal); later amendments are not incorporated in this text.