Endurance test: the purpose of the test is to provide evidence that the hydrogen components are capable of continuous reliable operation. The test consists of carrying out a specific number of test cycles for the hydrogen component under specified temperature and pressure conditions. A test cycle means the normal operation (i.e. one opening and one closing) of the hydrogen component.