(a)

Burst test: the purpose of the test is to provide the value of the pressure at which the container bursts. In order to prove this, the container is pressurised to a given value, which must be higher than the nominal working pressure of the container. The burst pressure of the container must exceed a specified pressure. The burst pressure of the container must be recorded and be kept by the manufacturer throughout the service life of the container.