(g)
Composite flaw tolerance test: the purpose of the test is to provide evidence that the hydrogen container is capable of resisting exposure to high pressure. In order to prove this, flaws of specified geometry are cut into the container sidewall and a specified number of pressure cycles carried out. The container must not leak or rupture within a number of cycles, but may fail by leakage during the remaining test cycles. The number of cycles to failure, along with the location and description of the failure, must be recorded.