anx_V__para__6
5. Internal leakage test: the purpose of the test is to provide evidence that the specified hydrogen components are free from internal leakage. In order to prove this, the hydrogen components are pressurised under different temperature conditions and observed for leakage. The hydrogen components must stay bubble free and must not leak internally at a higher rate than a specified number.
← anx_V__para__5 · All articles · anx_V__para__7 →
Source: EUR-Lex (Cellar) · retrieved 2026-10-31 · Text as adopted (Official Journal); later amendments are not incorporated in this text.