(c)
General conditions: Measurements shall be made at an ambient temperature of 23 °C +/– 5 °C. Measurements shall be made using a dynamic broadcast-content video signal representing typical broadcast TV content. The measurement shall be the average power consumed over 10 consecutive minutes. Measurements shall be made after the television has been in the off-mode for a minimum of 1 hour immediately followed by a minimum of 1 hour in the on-mode and shall be completed before a maximum of 3 hours in on-mode. The relevant video signal shall be displayed during the entire on-mode duration. For televisions that are known to stabilise within 1 hour, these durations may be reduced if the resulting measurement can be shown to be within 2 % of the results that would otherwise be achieved using the durations described here. Measurements shall be made with an uncertainty of less than or equal to 2 % at the 95 % confidence level. Measurements shall be made with the Automatic Brightness Control function, if such a function exists, made inactive. If the Automatic Brightness Control function exitsts and cannot be made inactive, then the measurements shall be performed with the light entering directly into the ambient light sensor at a level of 300 lux, or more.