lexiara

anx_II__cpt_1__cpt_1__table_3

A2. Materials Processing No Description Related item from Annex I to Regulation (EC) No 428/2009 II.A2.001 Vibration test systems, equipment and components thereof, other than those specified in 2B116: a. Vibration test systems employing feedback or closed loop techniques and incorporating a digital controller, capable of vibrating a system at an acceleration equal to or greater than 0,1 g rms between 0,1 Hz and 2 kHz and imparting forces equal to or greater than 50 kN, measured 'bare table'; b. Digital controllers, combined with specially designed vibration test 'software', with a real-time bandwidth greater than 5 kHz designed for use with vibration test systems specified in a.; c. Vibration thrusters (shaker units), with or without associated amplifiers, capable of imparting a force equal to or greater than 50 kN, measured 'bare table', and usable in vibration test systems specified in a.; d. Test piece support structures and electronic units designed to combine multiple shaker units in a system capable of providing an effective combined force equal to or greater than 50 kN, measured 'bare table', and usable in vibration systems specified in a. Technical Note: 'Bare table' means a flat table, or surface, with no fixture or fittings. 2B116 II.A2.002 Machine tools and components and numerical controls for machine tools, as follows: a. Machine tools for grinding having positioning accuracies with "all compensations available" equal to or less (better) than 15 μm according to ISO 230/2 (1988) (1) or national equivalents along any linear axis; Note: This item does not cover machine tools for grinding defined in items 2B201.b and 2B001.c. b. Components and numerical controls, specially designed for machine tools specified in 2B001, 2B201, or under a. 2B201.b 2B001.c II.A2.003 Balancing machines and related equipment as follows: a. Balancing machines, designed or modified for dental or other medical equipment, having all the following characteristics: 1. Not capable of balancing rotors/assemblies having a mass greater than 3 kg; 2. Capable of balancing rotors/assemblies at speeds greater than 12500 rpm; 3. Capable of correcting imbalance in two planes or more; and 4. Capable of balancing to a residual specific imbalance of 0,2 g × mm per kg of rotor mass; b. Indicator heads designed or modified for use with machines specified in a. above. Technical Note: Indicator heads are sometimes known as balancing instrumentation. 2B119 II.A2.004 Remote manipulators that can be used to provide remote actions in radiochemical separation operations or hot cells, other than those specified in 2B225, having either of the following characteristics: a. A capability of penetrating a hot cell wall of 0,3 m or more (through the wall operation); or b. A capability of bridging over the top of a hot cell wall with a thickness of 0,3 m or more (over the wall operation). 2B225 II.A2.006 Furnaces capable of operation at temperatures above 400 °C as follows: a. Oxidation furnaces b. Controlled atmosphere heat treatment furnaces Note: This item does not cover tunnel kilns with roller or car conveyance, tunnel kilns with conveyor belt, pusher type kilns or shuttle kilns, specially designed for the production of glass, tableware ceramics or structural ceramics. 2B226 2B227 II.A2.007 "Pressure transducers", other than those defined in 2B230, capable of measuring absolute pressures at any point in the range 0 to 200 kPa and having both of the following characteristics: a. Pressure sensing elements made of or protected by "Materials resistant to corrosion by uranium hexafluoride (UF_(6))", and b. Having either of the following characteristics: 1. A full scale of less than 200 kPa and an "accuracy" of better than ± 1 % of full scale; or 2. A full scale of 200 kPa or greater and an "accuracy" of better than 2 kPa. 2B230 II.A2.011 Centrifugal separators, capable of continuous separation without the propagation of aerosols and manufactured from: 1. Alloys with more than 25 % nickel and 20 % chromium by weight; 2. Fluoropolymers; 3. Glass (including vitrified or enamelled coating or glass lining); 4. Nickel or alloys with more than 40 % nickel by weight; 5. Tantalum or tantalum alloys; 6. Titanium or titanium alloys; or 7. Zirconium or zirconium alloys. Note: This item does not cover centrifugal separators defined in item 2B352.c. 2B352.c II.A2.012 Sintered metal filters made of nickel or nickel alloy with more than 40 % nickel by weight. Note: This item does not cover filters defined in item 2B352.d. 2B352.d II.A2.013 Spin-forming machines and flow-forming machines, other than those controlled by 2B009, 2B109 or 2B209, having a roller force of more than 60 kN and specially designed components therefor. Technical Note: For the purpose of II.A2.013, machines combining the functions of spin-forming and flow-forming are regarded as flow-forming machines. — II.A2.014 Liquid-liquid contacting equipment (mixer-settlers, pulsed columns, centrifugal contactors); and liquid distributors, vapour distributors or liquid collectors designed for such equipment where all surfaces that come in direct contact with the chemical(s) being processed are any of the following: N.B. SEE ALSO IV.A2.008. a. Made from any of the following materials: 1. Alloys with more than 25 % nickel and 20 % chromium by weight; 2. Fluoropolymers; 3. Glass (including vitrified or enamelled coating or glass lining); 4. Graphite or 'carbon graphite'; 5. Nickel or alloys with more than 40 % nickel by weight; 6. Tantalum or tantalum alloys; 7. Titanium or titanium alloys; or 8. Zirconium or zirconium alloys; or b. Made from both stainless steel and one or more of the materials specified in II.A2.014.a. Technical Note: 'Carbon graphite' is a composition consisting of amorphous carbon and graphite, in which the graphite content is 8 % or more by weight. 2B350.e II.A2.015 Industrial equipment and components, other than those specified in 2B350.d, as follows: N.B. SEE ALSO IV.A2.009. Heat exchangers or condensers with a heat transfer surface area greater than 0,05 m^(2), and less than 30 m^(2); and tubes, plates, coils or blocks (cores) designed for such heat exchangers or condensers, where all surfaces that come in direct contact with the fluid(s) are any of the following: a. Made from any of the following materials: 1. Alloys with more than 25 % nickel and 20 % chromium by weight; 2. Fluoropolymers; 3. Glass (including vitrified or enamelled coating or glass lining); 4. Graphite or 'carbon graphite'; 5. Nickel or alloys with more than 40 % nickel by weight; 6. Tantalum or tantalum alloys; 7. Titanium or titanium alloys; 8. Zirconium or zirconium alloys; 9. Silicon carbide; or 10. Titanium carbide; or b. Made from both stainless steel and one or more of the materials specified in II.A2.015.a. Note: This item does not cover vehicle radiators. Technical Note: The materials used for gaskets and seals and other implementation of sealing functions do not determine the status of control of the heat exchanger. 2B350.d II.A2.016 Multiple-seal, and seal-less pumps, other than those specified in 2B350.i, suitable for corrosive fluids, with manufacturer's specified maximum flow-rate greater than 0,6 m^(3)/hour, or vacuum pumps with manufacturer's specified maximum flow-rate greater than 5 m^(3)/hour [measured under standard temperature (273 K or 0 °C) and pressure (101,3 kPa) conditions]; and casings (pump bodies), preformed casing liners, impellers, rotors or jet pump nozzles designed for such pumps, in which all surfaces that come in direct contact with the chemical(s) being processed are any of the following: NB. SEE ALSO IV.A2.010. a. Made from any of the following materials: 1. Alloys with more than 25 % nickel and 20 % chromium by weight; 2. Ceramics; 3. Ferrosilicon; 4. Fluoropolymers; 5. Glass (including vitrified or enamelled coatings or glass lining); 6. Graphite or 'carbon graphite' 7. Nickel or alloys with more than 40 % nickel by weight; 8. Tantalum or tantalum alloys; 9. Titanium or titanium alloys; 10. Zirconium or zirconium alloys; 11. Niobium (columbium) or niobium alloys; or 12. Aluminium alloys; or b. Made from both stainless steel and one or more of the materials specified in II.A2.016.a. Technical Note: The materials used for gaskets and seals and other implementation of sealing functions do not determine the status of control of the pump. 2B350.i

· All articles ·

Source: EUR-Lex (Cellar) · retrieved 2026-11-10 · Text as adopted (Official Journal); later amendments are not incorporated in this text.