lexiara

MODULE H: Conformity based on full quality assurance

1. Conformity based on full quality assurance is the conformity assessment procedure whereby the manufacturer fulfils the obligations laid down in points 2 and 5, and ensures and declares on his sole responsibility that the pyrotechnic articles concerned satisfy the requirements of this Directive that apply to them. The manufacturer shall operate an approved quality system for design, manufacture and final product inspection and testing of the pyrotechnic articles concerned as specified in point 3 and shall be subject to surveillance as specified in point 4. The manufacturer shall lodge an application for assessment of his quality system with the notified body of his choice for the pyrotechnic articles concerned. The application shall include: the name and address of the manufacturer; the technical documentation for one model of each pyrotechnic article category intended to be manufactured. The technical documentation shall, wherever applicable, contain at least the following elements: a general description of the pyrotechnic article; conceptual design and manufacturing drawings and schemes of components, sub-assemblies, circuits, etc.; descriptions and explanations necessary for the understanding of those drawings and schemes and the operation of the pyrotechnic article; a list of the harmonised standards applied in full or in part, the references of which have been published in the Official Journal of the European Union, and, where those harmonised standards have not been applied, descriptions of the solutions adopted to meet the essential safety requirements of this Directive, including a list of other relevant technical specifications applied. In the event of partly applied harmonised standards, the technical documentation shall specify the parts which have been applied; results of design calculations made, examinations carried out, etc.; test reports; the documentation concerning the quality system; a written declaration that the same application has not been lodged with any other notified body. The quality system shall ensure compliance of the pyrotechnic articles with the applicable requirements of this Directive. All the elements, requirements and provisions adopted by the manufacturer shall be documented in a systematic and orderly manner in the form of written policies, procedures and instructions. That quality system documentation shall permit a consistent interpretation of the quality programmes, plans, manuals and records. It shall, in particular, contain an adequate description of: the quality objectives and the organisational structure, responsibilities and powers of the management with regard to design and product quality; the technical design specifications, including standards that will be applied and, where the relevant harmonised standards will not be applied in full, the means that will be used to ensure that the essential safety requirements of this Directive will be met; the design control and design verification techniques, processes and systematic actions that will be used when designing the pyrotechnic articles pertaining to the pyrotechnic article category covered; the corresponding manufacturing, quality control and quality assurance techniques, processes and systematic actions that will be used; the examinations and tests that will be carried out before, during and after manufacture, and the frequency with which they will be carried out; the quality records, such as inspection reports and test data, calibration data, qualification reports on the personnel concerned, etc.; the means of monitoring the achievement of the required design and product quality and the effective operation of the quality system. The notified body shall assess the quality system to determine whether it satisfies the requirements referred to in point 3.2. It shall presume conformity with those requirements in respect of the elements of the quality system that comply with the corresponding specifications of the relevant harmonised standard. In addition to experience in quality management systems, the auditing team shall have at least one member experienced as an assessor in the relevant product field and product technology concerned, and knowledge of the applicable requirements of this Directive. The audit shall include an assessment visit to the manufacturer’s premises. The auditing team shall review the technical documentation referred to in point 3.1(b) to verify the manufacturer’s ability to identify the applicable requirements of this Directive and to carry out the necessary examinations with a view to ensuring compliance of the pyrotechnic article with those requirements. The manufacturer shall be notified of the decision. The notification shall contain the conclusions of the audit and the reasoned assessment decision. The manufacturer shall undertake to fulfil the obligations arising out of the quality system as approved and to maintain it so that it remains adequate and efficient. The manufacturer shall keep the notified body that has approved the quality system informed of any intended change to the quality system. The notified body shall evaluate any proposed changes and decide whether the modified quality system will continue to satisfy the requirements referred to in point 3.2 or whether a reassessment is necessary. It shall notify the manufacturer of its decision. The notification shall contain the conclusions of the examination and the reasoned assessment decision. The purpose of surveillance is to make sure that the manufacturer duly fulfils the obligations arising out of the approved quality system. The manufacturer shall, for assessment purposes, allow the notified body access to the design, manufacture, inspection, testing and storage sites and shall provide it with all necessary information, in particular: the quality system documentation; the quality records as provided for by the design part of the quality system such as the results of analyses, calculations, tests, etc.; the quality records as provided for by the manufacturing part of the quality system such as inspection reports and test data, calibration data, qualification reports on the personnel concerned, etc. The notified body shall carry out periodic audits to make sure that the manufacturer maintains and applies the quality system and shall provide the manufacturer with an audit report. In addition, the notified body may pay unexpected visits to the manufacturer. During such visits, the notified body may, if necessary, carry out product tests, or have them carried out, in order to check the proper functioning of the quality system. It shall provide the manufacturer with a visit report and, if tests have been carried out, with a test report. The manufacturer shall affix the CE marking and, under the responsibility of the notified body referred to in point 3.1, the latter’s identification number to each individual pyrotechnic article that satisfies the applicable requirements of this Directive. The manufacturer shall draw up a written EU declaration of conformity for each product model and keep it at the disposal of the national authorities for 10 years after the pyrotechnic article has been placed on the market. The EU declaration of conformity shall identify the pyrotechnic article for which it has been drawn up. A copy of the EU declaration of conformity shall be made available to the relevant authorities upon request. 6. The manufacturer shall, for a period ending 10 years after the pyrotechnic article has been placed on the market, keep at the disposal of the national authorities: the technical documentation referred to in point 3.1; the documentation concerning the quality system referred to in point 3.1; the information relating to the change referred to in point 3.5, as approved; the decisions and reports of the notified body referred to in points 3.5, 4.3 and 4.4. 7. Each notified body shall inform its notifying authorities of quality system approvals issued or withdrawn and shall, periodically or upon request, make available to its notifying authorities the list of quality system approvals refused, suspended or otherwise restricted. Each notified body shall inform the other notified bodies of quality system approvals which it has refused, suspended or withdrawn, and, upon request, of quality system approvals which it has issued.

· All articles ·

Source: EUR-Lex (Cellar) · retrieved 2026-11-07 · Text as adopted (Official Journal); later amendments are not incorporated in this text.