The conformity assessment according to Module D, D1, F, F1 or G may be carried out at the manufacturer’s works or any other location if transport to the place of use does not require dismantling of the instrument, if the putting into service at the place of use does not require assembly of the instrument or other technical installation work likely to affect the instrument’s performance, and if the gravity value at the place of putting into service is taken into consideration or if the instrument’s performance is insensitive to gravity variations. In all other cases, it shall be carried out at the place of use of the instrument. If the instrument’s performance is sensitive to gravity variations the procedures referred to in point 7.1 may be carried out in two stages, with the second stage comprising all examinations and tests of which the outcome is gravity-dependent, and the first stage all other examinations and tests. The second stage shall be carried out at the place of use of the instrument. If a Member State has established gravity zones on its territory the expression ‘at the place of use of the instrument’ may be read as ‘in the gravity zone of use of the instrument’. Where a manufacturer has opted for execution in two stages of one of the procedures mentioned in point 7.1, and where these two stages will be carried out by different parties, an instrument which has undergone the first stage of the procedure shall bear the identification number of the notified body involved in that stage. The party which has carried out the first stage of the procedure shall issue for each of the instruments a certificate containing the data necessary for identification of the instrument and specifying the examinations and tests that have been carried out. The party which carries out the second stage of the procedure shall carry out those examinations and tests that have not yet been carried out. The manufacturer or his authorised representative shall ensure that he is able to supply the notified body’s certificates of conformity on request. A manufacturer who has opted for Module D or D1 in the first stage may either use this same procedure in the second stage or decide to continue in the second stage with Module F or F1 as appropriate. The CE marking and the supplementary metrology marking shall be affixed to the instrument on completion of the second stage, along with the identification number of the notified body which took part in the second stage.

· All articles ·

Source: EUR-Lex (Cellar) · retrieved 2026-11-05 · Text as adopted (Official Journal); later amendments are not incorporated in this text.