lexiara

3.3.3.

The partial weighing ranges are classified according to Table 2. All partial weighing ranges shall fall into the same accuracy class, that class being the instrument’s accuracy class. Table 2 For i = r, the corresponding column of Table 1 applies, with e replaced by e_(r.) Multi-interval instruments i= 1, 2, … r i= partial weighing range number r= total number of partial weighing ranges Class Verification scale interval (e) Minimum capacity (Min) Number of verification scale intervals Minimum value Minimum value n((Max_(i))(e_((i 1)))) Maximum value n((Max_(i))(e_(i))) I 0,001 g ≤ e_(i) 100 e_(1) 50000 — II 0,001 g ≤ e_(i) ≤ 0,05 g 20 e_(1) 5000 100000 0,1 g ≤ e_(i) 50 e_(1) 5000 100000 III 0,1 g ≤ e_(i) 20 e_(1) 500 10000 IIII 5g ≤ e_(i) 10 e_(1) 50 1000

· All articles ·