4. Accuracy

On implementation of the procedures laid down in Article 13, the error of indication shall not exceed the maximum permissible error of indication as shown in Table 3. In the case of digital indication the error of indication shall be corrected for the rounding error. The maximum permissible errors apply to the net value and tare value for all possible loads, excluding preset tare values. Table 3 Maximum permissible errors Load Maximum permissible error Class I Class II Class III Class IIII 0 ≤ m ≤ 50000 e 0 ≤ m ≤ 5000 e 0 ≤ m ≤ 500 e 0 ≤ m ≤ 50 e ± 0,5 e 50000 e < m ≤ 200000 e 5000 e < m ≤ 20000 e 500 e < m ≤ 2000 e 50 e < m ≤ 200 e ± 1,0 e 200000 e < m 20000 e < m ≤ 100000 e 2000 e < m ≤ 10000 e 200 e < m ≤ 1000 e ± 1,5 e The maximum permissible errors in service are twice the maximum permissible errors fixed in Section 4.1.