5.
The MPE, positive or negative, on volumes delivered at flowrates between the transitional flowrate (Q_(2)) (included) and the overload flowrate (Q_(4)) is: 2 % for water having a temperature ≤ 30 °C, 3 % for water having a temperature > 30 °C. The meter shall not exploit the MPE or systematically favour any party.
← MPE · All articles · anx_III__cpt_3__cpt_2__point_5__text_1 →