7.2.1.

The variation of the measurement result after the durability test, when compared with the initial measurement result, shall not exceed: 3 % of the metered volume between Q_(1) included and Q_(2) excluded; 1,5 % of the metered volume between Q_(2) included and Q_(4) included.