2.1. Gas meter indicating the volume at metering conditions or mass
Table 1 Class 1,5 1,0 Q_(min) ≤ Q < Q_(t) 3 % 2 % Q_(t) ≤ Q ≤ Q_(max) 1,5 % 1 % The gas meter shall not exploit the MPEs or systematically favour any party.
← 2. Maximum permissible error (MPEs) · All articles · anx_IV__cpt_3__cpt_2__cpt_1__table_1 →