7. Performance Under Influence Factors And Electromagnetic Disturbances

7.1. The MPEs due to influence factors are: 7.1.1. For category X instruments: For automatic operation; as specified in Tables 1 and 2, For static weighing in non-automatic operation; as specified in Table 1. For each load in automatic operation; as specified in Table 1, For static weighing in non-automatic operation; as specified for category X in Table 1. 7.2. The critical change value due to a disturbance is one verification scale interval. 7.3. Temperature range: For class XI and Y(I) the minimum range is 5 °C, For class XII and Y(II) the minimum range is 15 °C.