3. Performance Under Influence Factor And Electromagnetic Disturbance
The MPE due to influence factors shall be as specified in point 2.1. The critical change value due to a disturbance is a change of the static weight indication equal to the MPE as specified in point 2.1 calculated for the rated minimum fill, or a change that would give equivalent effect on the fill in the case of instruments where the fill consists of multiple loads. The calculated critical change value shall be rounded to the next higher scale interval (d). The manufacturer shall specify the value of the rated minimum fill.