1. Rated operating conditions

The manufacturer shall specify the rated operating conditions for the instrument, in particular; The flowrate range is subject to the following conditions: the flowrate range of a measuring system shall be within the flowrate range of each of its elements, in particular the meter. meter and measuring system: Table 1 Specific measuring system Characteristic of liquid Minimum ratio of Q_(max): Q_(min) Fuel dispensers Not Liquefied gases 10: 1 Liquefied gases 5: 1 Measuring system Cryogenic liquids 5: 1 Measuring systems on pipeline and systems for loading ships All liquids Suitable for use All other measuring systems All liquids 4: 1 1.2. The properties of the liquid to be measured by the instrument by specifying the name or type of the liquid or its relevant characteristics, for example: Temperature range; Pressure range; Density range; Viscosity range. 1.3. The nominal value of the AC voltage supply and/or limits of the DC voltage supply. 1.4. The base conditions for converted values. Note: Point 1.4 is without prejudice to the Member States’ obligations to require use of a temperature of either 15 °C in accordance with Article 12(2) of Council Directive 2003/96/EC of 27 October 2003 restructuring the Community framework for the taxation of energy products and electricity OJ L 283, 31.10.2003, p. 51. .