lexiara

1. Rated operating conditions

The values of the rated operating conditions shall be specified by the manufacturer as follows: For the temperature of the liquid: θ_(max), θ_(min), for the temperature differences: Δθ_(max), Δθ_(min), subject to the following restrictions: Δθ_(max)Δθ_(min) 10; Δθ_(min) = 3 K or 5 K or 10 K. For the pressure of the liquid: The maximum positive internal pressure that the thermal energy meter can withstand permanently at the upper limit of the temperature. For the flow rates of the liquid: q_(s), q_(p), q_(i), where the values of q_(p) and q_(i) are subject to the following restriction: q_(p)q_(i) 10. For the thermal power: P_(s).