I = the electrical current flowing through the meter; I_(n) = the specified reference current for which the transformer operated meter has been designed; I_(st) = the lowest declared value of I at which the meter registers active electrical energy at unity power factor (polyphase meters with balanced load); I_(min) = the value of I above which the error lies within maximum permissible errors (MPEs) (polyphase meters with balanced load); I_(tr) = the value of I above which the error lies within the smallest MPE corresponding to the class index of the meter; I_(max) = the maximum value of I for which the error lies within the MPEs; U = the voltage of the electricity supplied to the meter; U_(n) = the specified reference voltage; f = the frequency of the voltage supplied to the meter; f_(n) = the specified reference frequency; PF = power factor = cosφ = the cosine of the phase difference φ between I and U.