anx_V__cpt_3__cpt_2__table_1
Table 1 For Class B electromechanical meters I_(min)0,4 I_(tr) shall apply. Class A Class B Class C For direct-connected meters I_(st) 0,05 I_(tr) 0,04 I_(tr) 0,04 I_(tr) I_(min) 0,5 I_(tr) 0,5 I_(tr) 0,3 I_(tr) I_(max) 50 I_(tr) 50 I_(tr) 50 I_(tr) For transformer-operated meters I_(st) 0,06 I_(tr) 0,04 I_(tr) 0,02 I_(tr) I_(min) 0,4 I_(tr) 0,2 I_(tr) 0,2 I_(tr) I_(n) 20 I_(tr) 20 I_(tr) 20 I_(tr) I_(max) 1,2 I_(n) 1,2 I_(n) 1,2 I_(n)
← anx_V__cpt_3__cpt_2__text_2 · All articles · anx_V__cpt_3__cpt_2__table_1__text_1 →
Source: EUR-Lex (Cellar) · retrieved 2026-11-06 · Text as adopted (Official Journal); later amendments are not incorporated in this text.