The resolution shall be equal to or of one order of magnitude higher than the values shown in Table 3. Table 3 0,01 % vol for measurand values below or equal to 4 % vol, otherwise 0,1 % vol. Resolution CO CO_(2) O_(2) HC Class 0 and class I 0,01 % vol 0,1 % vol 1 ppm vol The lambda value shall be displayed with a resolution of 0,001.