1.4. Control of loading (including overspeed)

Lifts must be so designed, constructed and installed as to prevent normal starting if the rated load is exceeded. Lifts must be equipped with an overspeed governor. These requirements do not apply to lifts in which the design of the drive system prevents overspeed. Fast lifts must be equipped with a speed-monitoring and speed-limiting device. Lifts driven by friction pulleys must be designed so as to ensure stability of the traction cables on the pulley.