4. Verification

The notified body chosen by the installer shall examine the technical documentation and the lift and carry out the appropriate tests as set out in the relevant harmonised standard(s), or equivalent tests, to check its conformity with the applicable essential health and safety requirements set out in Annex I. The tests shall include at least the tests referred to in point 3.3 of Annex V. If the lift meets the essential health and safety requirements set out in Annex I the notified body shall issue a certificate of conformity relating to the tests carried out. The notified body shall fill in the corresponding pages of the logbook referred to in point 6.2 of Annex I. If the notified body refuses to issue the certificate of conformity, it shall state in detail its reasons for refusal and indicate the necessary corrective measures to be taken. When the installer reapplies for unit verification he shall apply to the same notified body. On request, the notified body shall provide the Commission and the Member States with a copy of the certificate of conformity.