lexiara

ANNEX II

Normal power recharging points for motor vehicles Alternating current (AC) normal power recharging points for electric vehicles shall be equipped, for interoperability purposes, at least with socket outlets or vehicle connectors of Type 2 as described in standard EN 62196-2. While maintaining the Type 2 compatibility, those socket outlets may be equipped with features such as mechanical shutters. High power recharging points for motor vehicles Alternating current (AC) high power recharging points for electric vehicles shall be equipped, for interoperability purposes, at least with connectors of Type 2 as described in standard EN 62196-2. Direct current (DC) high power recharging points for electric vehicles shall be equipped, for interoperability purposes, at least with connectors of the combined charging system ‘Combo 2’ as described in standard EN 62196-3. Wireless recharging points for motor vehicles Battery swapping for motor vehicles Recharging points for L-category motor vehicles Recharging points for electric buses Shore-side electricity supply for seagoing ships Shore-side electricity supply for seagoing ships, including the design, installation and testing of the systems, shall comply with the technical specifications of the IEC/ISO/IEEE 80005-1 standard. Shore-side electricity supply for inland waterway vessels Outdoor hydrogen refuelling points dispensing gaseous hydrogen used as fuel on board motor vehicles shall comply with the technical specifications of the ISO/TS 20100 Gaseous Hydrogen Fuelling specification. The hydrogen purity dispensed by hydrogen refuelling points shall comply with the technical specifications included in the ISO 14687-2 standard. Hydrogen refuelling points shall employ fuelling algorithms and equipment complying with the ISO/TS 20100 Gaseous Hydrogen Fuelling specification. Connectors for motor vehicles for the refuelling of gaseous hydrogen shall comply with the ISO 17268 gaseous hydrogen motor vehicle refuelling connection devices standard. Technical specifications for refuelling points for LNG for inland waterway vessels or sea-going ships Technical specifications for refuelling points for LNG for motor vehicles Technical specifications for CNG connectors/receptacles CNG connectors/receptacles shall comply with UNECE Regulation No 110 (referring to ISO 14469, parts I and II). Technical specifications for CNG refuelling points for motor vehicles

· All articles ·

Source: EUR-Lex (Cellar) · retrieved 2026-11-03 · Text as adopted (Official Journal); later amendments are not incorporated in this text.