lexiara

anx_V__para__2

The noise during venting the pressure regulator is measured with the engine at idling speed. The ventilating noise is registered while operating the service and parking brakes; before each measurement, the air-compressor unit has to be brought up to the highest permissible operating pressure, and then the engine switched off.

· All articles ·

Source: EUR-Lex (Cellar) · retrieved 2026-11-19 · Text as adopted (Official Journal); later amendments are not incorporated in this text.