Test apparatus
Inlet flange or sleeve — connection to the rear of complete silencing system to be tested. Regulation valve (hand operated). Compensating reservoir from 35 to 40 l. Pressure switch 5 kPa to 250 kPa — to open item 7. Time delay switch — to close item 7. Counter of impulses. Quick response valve — such as the valve of an exhaust brake system of 60 mm in diameter, operated by a pneumatic cylinder with an output of 120 N at 400 kPa. The response time, both when opening and closing, shall not exceed 0,5 s. Exhaust gas evacuation. Flexible pipe. Pressure gauge.