lexiara

2. Method B: Bunker fuel tank monitoring on-board

This method is based on fuel tank readings for all fuel tanks on-board. The tank readings shall occur daily when the ship is at sea and each time the ship is bunkering or de-bunkering. The cumulative variations of the fuel tank level between two readings constitute the fuel consumed over the period. The period means the time between two port calls or time within a port. For the fuel used during a period, the fuel type and the sulphur content need to be specified. Fuel tank readings shall be carried out by appropriate methods such as automated systems, soundings and dip tapes. The method for tank sounding and uncertainty associated shall be specified in the monitoring plan. Where the amount of fuel uplift or the amount of fuel remaining in the tanks is determined in units of volume, expressed in litres, the company shall convert that amount from volume to mass by using actual density values. The company shall determine the actual density by using one of the following: on-board measurement systems; the density measured by the fuel supplier at fuel uplift and recorded on the fuel invoice or BDN; the density measured in a test analysis conducted in an accredited fuel test laboratory, where available. The actual density shall be expressed in kg/l and determined for the applicable temperature for a specific measurement. In cases for which actual density values are not available, a standard density factor for the relevant fuel type shall be applied once assessed by the verifier.