3.9.2.2. Protection against external irradiation
PPE intended to provide complete user protection against external irradiation or, failing this, adequate attenuation thereof, must be designed to counter only weak electron (e.g. beta) or weak photon (e.g. X, gamma) radiation. The constituent materials and other components of these types of PPE must be chosen or designed and incorporated so as to provide the degree of user protection required by the foreseeable conditions of use without leading to an increase in exposure time as a result of the impedance of user gestures, posture or movement (see point 1.3.2). PPE must bear a mark indicating the type and equivalent thickness of the constituent material(s) suitable for the foreseeable conditions of use.