2.3. Product checks

A notified body, chosen by the manufacturer, shall carry out product checks or have them carried out at intervals of one year or less, in order to verify the quality of the internal checks on the appliance or the fitting, taking into account, inter alia, the technological complexity of the appliances or the fittings and the quantity of production. An adequate sample of the final appliances or fittings taken on site by the notified body before the placing on the market, shall be examined and appropriate tests as identified by the relevant parts of the harmonised standards, and/or equivalent tests set out in other relevant technical specifications, shall be carried out in order to check the conformity of the appliance or the fitting with the relevant requirements of this Regulation. Where a sample does not conform to the acceptable quality level, the notified body shall take appropriate measures. The acceptance sampling procedure to be applied is intended to determine whether the manufacturing process of the appliance or the fitting performs within acceptable limits, with a view to ensuring conformity of the appliance or the fitting. The manufacturer shall, under the responsibility of the notified body, affix the notified body's identification number during the manufacturing process.