lexiara

anx_IV__table

Text with EEA relevance.

Parameter | Verification tolerances On mode power demand, (Pmeasured , Watts) excluding allowances and adjustments in Annex II, point B, for the purposes of EEI calculation set out in Annex II, point A. | The determined value (*1) shall not exceed the declared value by more than 7 % Off mode, standby mode and networked standby mode power demand (Watts), as applicable | The determined value (*1) shall not exceed the declared value by more than 0,10 Watt if the declared value is 1,00 W or less, or by more than 10 % if the declared value is more than 1,00 W Peak white luminance ratio | Where applicable, the determined value shall not be lower than 60 % of the peak white luminance of the brightest on mode configuration provided by the electronic display Peak white luminance (cd/m2) | The determined value (*1) shall not be lower than the declared value by more than 8 % Visible screen diagonal in centimetres (and inches, if declared) | The determined value (*1) shall not be lower than the declared value by more than 1 cm (or 0,4 inches). Screen area in dm2 | The determined value (*1) shall not be lower than the declared value by more than 0,1 dm2 Timed functions as set out in Annex II, points C.3 and C.4 | The switch shall be completed within 5 seconds of the set out values Weight of plastic components as qualified in Annex II, point D.2 | The determined value (*1) shall not be different from the declared value by more than 5 grams

· All articles ·

Source: EUR-Lex (Cellar) · retrieved 2026-11-19 · Text as adopted (Official Journal); later amendments are not incorporated in this text.