anx_V__para__17
This test shall evaluate the safety performance of a battery in internal short-circuit situations. The occurrence of internal short circuits, one of the main concerns for battery manufacturers, potentially leads to venting, thermal runaway, and sparking which can ignite the electrolyte vapours escaping from the cell. The generation of such internal short circuits can be triggered by manufacturing imperfections, the presence of impurities in the cells or dendritic growth of lithium, and is the cause of most in-field safety incidents. Multiple internal short circuit scenarios are possible (e.g. electrical contact of cathode/anode, aluminium current collector/copper current collector, aluminium current collector/anode) each with a different contact resistance.